Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 13.652
Filtrar
1.
IEEE J Transl Eng Health Med ; 12: 340-347, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38606389

RESUMO

OBJECTIVE: Cemented total hip arthroplasty (THA) demonstrates superior survival rates compared to uncemented procedures. Nevertheless, most younger patients opt for uncemented THA, as removing well-fixed bone cement in the femur during revisions is complex, particularly the distal cement plug. This removal procedure often increases the risk of femoral fracture or perforation, haemorrhage and weakening bone due to poor drill control and positioning. Aim of this study was to design a novel drill guide to improve drill positioning. METHODS AND PROCEDURES: A novel orthopaedic drill guide was developed, featuring a compliant centralizer activated by a drill guide actuator. Bone models were prepared to assess centralizing performance. Three conditions were tested: drilling without guidance, guided drilling with centralizer activation held, and guided drilling with centralizer activation released. Deviations from the bone centre were measured at the entry and exit point of the drill. RESULTS: In the centralizing performance test, the drill guide significantly reduced drill hole deviations in both entry and exit points compared to the control ([Formula: see text]). The absolute deviation on the exit side of the cement plug was 10.59mm (SD 1.56) for the 'No drill guide' condition, 3.02mm (SD 2.09) for 'Drill guide - hold' and 2.12mm (SD 1.71) for 'Drill guide - release'. The compliant drill guide centralizer significantly lowered the risk of cortical bone perforation during intramedullary canal drilling in the bone models due to better control of the cement drill position. Clinical and Translational Impact Statement: The drill guide potentially reduces perioperative risks in cemented femoral stem revision. Future research should identify optimal scenarios for its application.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Ortopedia , Humanos , Artroplastia de Quadril/efeitos adversos , Reoperação , Fêmur/cirurgia , Cimentos Ósseos/uso terapêutico
2.
BMC Musculoskelet Disord ; 25(1): 285, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609902

RESUMO

OBJECTIVE: To investigate the effect of bone cement on the vertebral body and biomechanical properties in percutaneous cement discoplasty (PCD) for degenerative lumbar disc disease. METHODS: Three-dimensional reconstruction of L2 ~ L3 vertebral bodies was performed in a healthy volunteer, and the corresponding finite element model of the spine was established. Biomechanical analysis was performed on the changes in stress distribution in different groups of models by applying quantitative loads. RESULTS: Models with percutaneous discoplasty (PCD) showed improved stability under various stress conditions, and intervertebral foraminal heights were superior to models without discoplasty. CONCLUSION: Cement discoplasty can improve the stability of the vertebral body to a certain extent and restore a certain height of the intervertebral foramen, which has a good development prospect and potential.


Assuntos
Escoliose , Humanos , Escoliose/diagnóstico por imagem , Escoliose/cirurgia , Análise de Elementos Finitos , Cimentos Ósseos/uso terapêutico , Coluna Vertebral , Voluntários Saudáveis
3.
ANZ J Surg ; 94(4): 724-732, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38572937

RESUMO

INTRODUCTION: Surgical glove perforation has been linked to a double-fold increased risk of surgical site infection. Infection in the context of arthroplasty can have devastating consequences. In orthopaedics, use of polymethyl methacrylate (PMMA) bone cement is commonplace, and the impact on glove strength and perforation risk is not fully understood. This study aimed to examine the resistance to perforation and thickness of gloves following PMMA exposure, in accordance with the International Organization for Standardization (ISO) standard for glove integrity. METHODS: Pairs of gloves were separated and randomly sorted into exposure and control groups. Twenty pairs of latex and 40 pairs of polyisoprene gloves were used. Exposure group glove cuffs were in contact with cement from a single surface of the glove for 13 min as cement cured. Force to perforation and glove thickness were tested in accordance with ISO guidelines. RESULTS: Latex gloves were found to have a significantly increased force to perforation following PMMA exposure (10.26 Newtons (N) vs. 9.81 N, P = 0.048). Both polyisoprene under- and over-gloves were shown to have no significant change in strength to perforation post exposure (9.69 N vs. 9.83 N, P = 0.561, and 10.26 N vs. 10.65 N, P = 0.168, respectively). All groups were over the ISO standard minimum strength of 5 N. CONCLUSIONS: Exposure of latex and polyisoprene surgical gloves to PMMA bone cement does not appear to increase glove perforation risk and rather may improve natural rubber latex glove strength. This study supports the use of latex and polyisoprene surgical gloves in procedures that involve the handling of PMMA bone cement.


Assuntos
Luvas Cirúrgicas , Ortopedia , Humanos , Polimetil Metacrilato/efeitos adversos , Cimentos Ósseos/efeitos adversos , Látex
4.
PLoS One ; 19(4): e0298761, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38598491

RESUMO

The intent of this study is to explore the physical properties and long-term performance of concrete made with metakaolin (MK) as a binder, using microsilica (MS) and nanosilica (NS) as substitutes for a portion of the ordinary Portland cement (OPC) content. The dosage of MS was varied from 5% to 15% for OPC-MK-MS blends, and the dosage of NS was varied from 0.5% to 1.5% for OPC-MK-NS blends. Incorporation of these pozzolans accelerated the hardening process and reduced the flowability, consistency, and setting time of the cement paste. In addition, it produced a denser matrix, improving the strength of the concrete matrix, as confirmed by scanning electron microscopy and X-ray diffraction analysis. The use of MS enhanced the strength by 10.37%, and the utilization of NS increased the strength by 11.48% at 28 days. It also reduced the penetrability of the matrix with a maximum reduction in the water absorption (35.82%) and improved the resistance to the sulfate attack for specimens containing 1% NS in the presence of 10% MK. Based on these results, NS in the presence of MK can be used to obtain cementitious structures with the enhanced strength and durability.


Assuntos
Cimentos Ósseos , Cimentos de Ionômeros de Vidro , Cristalografia por Raios X , Intenção , Microscopia Eletrônica de Varredura
5.
J Biomech ; 166: 112070, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38569456

RESUMO

Cement-augmentation is a technique commonly used during posterior lumbar instrumented fusion (PLIF) to reinforce compromised osteoporotic vertebral bone, minimize the risk of loosening screws, enhance stability, and improve overall surgical outcomes. In this study, we introduce a novel segmented vertebral body regional modeling approach to investigate the effects of osteoporosis and cement-augmented lumbar fusion on disc biomechanics at spinal levels adjacent to the fused vertebrae. Using our previously validated personalized-poroelastic-osteoligamentous FE model of the spine, fusion was simulated at L4-L5, and the biomechanics of adjacent levels were studied for 30 patients (non-osteoporotic patients (N = 15), osteoporotic patients (N = 15)). PLIF models, with and without cement-augmentation, were developed and compared after an 8 h-rest period (200 N), following a 16 h-cyclic compressive loading of 500-1000 N (40 and 20 min, respectively). Movement in different directions (flexion/ extension/ lateral bending/ axial rotation) was simulated using 10Nm moment before and after cyclic loading. The material mapping algorithm was validated by comparing the results of voxel-based and parametric models. The FE cement-augmented models, subject to daily activity loading, demonstrated significant differences in disc height loss and fluid loss as compared to non-cemented models. The calculated axial stress and fiber strain values were also significantly higher for these models. This work demonstrates that although osteoporosis does not significantly alter the time-dependent characteristics of adjacent IVDs post-surgery, cement-augmentation increases the risk of adjacent segment disease (ASD) incidence. A holistic understanding of the trade-offs and long-term complex interplay between structural reinforcement modalities, including cement augmentation, and altered biomechanics warrants further investigation.


Assuntos
Osteoporose , Fusão Vertebral , Humanos , Análise de Elementos Finitos , Vértebras Lombares/cirurgia , Osteoporose/cirurgia , Cimentos Ósseos , Fusão Vertebral/efeitos adversos , Fenômenos Biomecânicos
6.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 426-431, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632061

RESUMO

Objective: To explore the effectiveness of using antibiotic bone cement-coated plates internal fixation technology as a primary treatment for Gustilo type ⅢB tibiofibular open fractures. Methods: The clinical data of 24 patients with Gustilo type ⅢB tibiofibular open fractures who were admitted between January 2018 and December 2021 and met the selection criteria was retrospectively analyzed. Among them, there were 18 males and 6 females, aged from 25 to 65 years with an average age of 45.8 years. There were 3 cases of proximal tibial fracture, 6 cases of middle tibial fracture, 15 cases of distal tibial fracture, and 21 cases of fibular fracture. The time from injury to emergency surgery ranged from 3 to 12 hours, with an average of 5.3 hours. All patients had soft tissue defects ranging from 10 cm×5 cm to 32 cm×15 cm. The time from injury to skin flap transplantation for wound coverage ranged from 1 to 7 days, with an average of 4.1 days, and the size of skin flap ranged from 10 cm×5 cm to 33 cm×15 cm. Ten patients had bone defects with length of 2-12 cm (mean, 7.1 cm). After emergency debridement, the tibial fracture end was fixed with antibiotic bone cement-coated plates, and the bone defect area was filled with antibiotic bone cement. Within 7 days, the wound was covered with a free flap, and the bone cement was replaced while performing definitive internal fixation of the fracture. In 10 patients with bone defect, all the bone cement was removed and the bone defect area was grafted after 7-32 weeks (mean, 11.8 weeks). The flap survival, wound healing of the affected limb, complications, and bone healing were observed after operation, and the quality of life was evaluated according to the short-form 36 health survey scale (SF-36 scale) [including physical component summary (PCS) and mental component summary (MCS) scores] at 1 month, 6 months after operation, and at last follow-up. Results: All 24 patients were followed up 14-38 months (mean, 21.6 months). All the affected limbs were successfully salvaged and all the transplanted flaps survived. One case had scar hyperplasia in the flap donor site, and 1 case had hypoesthesia (grade S3) of the skin around the scar. There were 2 cases of infection in the recipient area of the leg, one of which was superficial infection after primary flap transplantation and healed after debridement, and the other was sinus formation after secondary bone grafting and was debrided again 3 months later and treated with Ilizarov osteotomy, and healed 8 months later. The bone healing time of the remaining 23 patients ranged from 4 to 9 months, with an average of 6.1 months. The scores of PCS were 44.4±6.5, 68.3±8.3, 80.4±6.9, and the scores of MCS were 59.2±8.2, 79.5±7.8, 90.0±6.6 at 1 month, 6 months after operation, and at last follow-up, respectively. The differences were significant between different time points ( P<0.05). Conclusion: Antibiotic bone cement-coated plates internal fixation can be used in the primary treatment of Gustilo type ⅢB tibiofibular open fractures, and has the advantages of reduce the risk of infection in fracture fixation, reducing complications, and accelerating the functional recovery of patients.


Assuntos
Fraturas Expostas , Lesões dos Tecidos Moles , Fraturas da Tíbia , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Tíbia/cirurgia , Cimentos Ósseos , Fraturas Expostas/cirurgia , Antibacterianos , Cicatriz/cirurgia , Estudos Retrospectivos , Qualidade de Vida , Resultado do Tratamento , Fraturas da Tíbia/cirurgia , Transplante de Pele , Fixação Interna de Fraturas/efeitos adversos , Lesões dos Tecidos Moles/cirurgia
7.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 474-479, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632069

RESUMO

Objective: To investigate the feasibility and effectiveness of antibiotic bone cement directly inducing skin regeneration technology in the repairing of wound in the lateral toe flap donor area. Methods: Between June 2020 and February 2023, antibiotic bone cement directly inducing skin regeneration technology was used to repair lateral toe flap donor area in 10 patients with a total of 11 wounds, including 7 males and 3 females. The patients' age ranged from 21 to 63 years, with an average of 40.6 years. There were 3 cases of the distal segment of the thumb, 2 cases of the distal segment of the index finger, 1 case of the middle segment of the index and middle fingers, 1 case of the distal segment of the middle finger, and 3 cases of the distal segment of the ring finger. The size of the skin defect of the hand ranged from 2.4 cm×1.8 cm to 4.3 cm×3.4 cm. The disease duration ranged from 1 to 15 days, with an average of 6.9 days. The flap donor sites were located at fibular side of the great toe in 5 sites, tibial side of the second toe in 5 sites, and tibial side of the third toe in 1 site. The skin flap donor site wounds could not be directly sutured, with 2 cases having exposed tendons, all of which were covered with antibiotic bone cement. Results: All patients were followed up 6 months to 2 years, with an average of 14.7 months. All the 11 flaps survived and had good appearance. The wound healing time was 40-72 days, with an average of 51.7 days. There was no hypertrophic scar in the donor site, which was similar to the color of the surrounding normal skin; the appearance of the foot was good, and wearing shoes and walking of the donor foot were not affected. Conclusion: It is a feasible method to repair the wound in the lateral foot flap donor area with the antibiotic bone cement directly inducing skin regeneration technology. The wound heals spontaneously, the operation is simple, and there is no second donor site injury.


Assuntos
Traumatismos dos Dedos , Retalho Perfurante , Procedimentos de Cirurgia Plástica , Lesões dos Tecidos Moles , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Cimentos Ósseos , Transplante de Pele , Traumatismos dos Dedos/cirurgia , Dedos do Pé/cirurgia , Lesões dos Tecidos Moles/cirurgia , Resultado do Tratamento
8.
Beijing Da Xue Xue Bao Yi Xue Ban ; 56(2): 371-374, 2024 Apr 18.
Artigo em Chinês | MEDLINE | ID: mdl-38595261

RESUMO

With the development of modern medical standards, autoimmune diseases and their associated successive osteoporosis have received increasing attention in recent years. Patients with autoimmune diseases, due to the characteristics of the disease and the prolonged use of glucocorticoid hormone therapy, may affect the bone formation and bone absorption of the patient, followed by severe successive osteoporosis, thereby increasing the risk of osteoporotic vertebral fractures. Vertebral compression fractures of the spine are common fracture types in patients with osteoporotic fractures. Osteoporosis is a common complication after glucocorticoid therapy in patients with autoimmune diseases. Percutaneous vertebroplasty (PVP) and percutaneous kyphoplasty (PKP) are minimally invasive operation and are commonly used surgical methods for the treatment of osteoporotic vertebral compression fractures. However, due to the operation of spinal puncture during the operation, there are serious surgical risks such as bone cement leakage, spinal epidural hemorrhage, subdural hemorrhage, and subarachnoid hemorrhage in both PVP and PKP. As a result, it is necessary to evaluate the patient' s body before surgery carefully, especially in the case of blood coagulation. This article reports a case of autoimmune disease patient admitted to Peking University People' s Hospital due to lumbar 4 vertebral compression fracture combined with Sjögren' s syndrome. The patient' s preoperative examination showed that the activated partial thromboplastin time (APTT) was significantly prolonged. After completing the APTT extended screening experiment and lupus anticoagulant factor testing, the multi-disciplinary team (MDT) of Peking University People' s Hospital jointly discussed the conclusion that the patient' s test results were caused by an abnormal self-immunity anti-copulant lupus (LAC). Based on the results of the laboratory examination, the patient was considered to be diagnosed with combined antiphospholipid syndrome (APS). For such patients, compared with the patient' s tendency to bleed, we should pay more attention to the risk of high blood clotting in the lower limbs of the patient, pulmonary clots and so on. With timely anti-coagulation treatment, the patient safely passed the peripheral period and was successfully discharged from the hospital. Therefore, for patients with autoimmune diseases with prolonged APTT in the perioperative period, doctors need to carefully identify the actual cause and carry out targeted treatment in order to minimize the risk of surgical and perioperative complications and bring satisfactory treatment results to the patients.


Assuntos
Doenças Autoimunes , Fraturas por Compressão , Cifoplastia , Osteoporose , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Vertebroplastia , Humanos , Fraturas da Coluna Vertebral/cirurgia , Fraturas da Coluna Vertebral/etiologia , Fraturas por Compressão/cirurgia , Vertebroplastia/efeitos adversos , Vertebroplastia/métodos , Tempo de Tromboplastina Parcial , Glucocorticoides , Tempo de Protrombina , Cifoplastia/efeitos adversos , Cifoplastia/métodos , Osteoporose/complicações , Fraturas por Osteoporose/cirurgia , Fraturas por Osteoporose/etiologia , Cimentos Ósseos , Resultado do Tratamento , Estudos Retrospectivos
9.
BMC Musculoskelet Disord ; 25(1): 290, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622692

RESUMO

BACKGROUND: The proximal femoral nail anti-rotation (PFNA) with cement enhancement enhances the anchorage ability of internal fixation in elderly with osteoporotic intertrochanteric fracture. However, whether it is superior to hemiarthroplasty is still controversial. The present study aimed to determine which treatment has better clinical outcomes among older patients. METHODS: We retrospectively analyzed 102 elderly patients with osteoporosis who developed intertrochanteric fractures and underwent PFNA combined with cement-enhanced internal fixation (n = 52, CE group), and hemiarthroplasty (n = 50, HA group) from September 2012 to October 2018. All the intertrochanteric fractures were classified according to the AO/OTA classification. Additionally, the operative time, intraoperative blood loss, intraoperative and postoperative blood transfusion rates, postoperative weight-bearing time, hospitalization time, Barthel Index of Activities Daily Living, Harris score of hip function, visual analog (VAS) pain score, and postoperative complications were compared between the two groups. RESULTS: The CE group had significantly shorter operative time, lesser intraoperative blood loss, lower blood transfusion rate, and longer postoperative weight-bearing time than the HA group. The CE group had lower Barthel's Index of Activities of Daily Living, lower Harris' score, and higher VAS scores in the first and third months after surgery than the HA group, but no difference was observed between the two groups from 6 months to 12 months. There was no significant difference in the total post-operative complications between the two groups. CONCLUSION: The use of PFNA combined with a cement-enhanced internal fixation technique led to shorter operative time and lesser intraoperative blood loss and trauma in elderly patients as compared to HA.


Assuntos
Fixação Intramedular de Fraturas , Hemiartroplastia , Fraturas do Quadril , Humanos , Idoso , Estudos Retrospectivos , Pinos Ortopédicos , Hemiartroplastia/efeitos adversos , Hemiartroplastia/métodos , Perda Sanguínea Cirúrgica/prevenção & controle , Atividades Cotidianas , Resultado do Tratamento , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Cimentos Ósseos/uso terapêutico , Complicações Pós-Operatórias/cirurgia , Fixação Intramedular de Fraturas/efeitos adversos
10.
J Orthop Surg Res ; 19(1): 240, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622736

RESUMO

OBJECTIVE: To assess the radiographic outcomes, clinical outcomes and complications of percutaneous kyphoplasty (PKP) with and without posterior pedicle screw fixation (PPSF) in the treatment of severe osteoporotic vertebral compression fractures (sOVCF) with nonunion. METHODS: This study involved 51 patients with sOVCF with nonunion who underwent PKP or PPSF + KP. The operation time, intraoperative blood loss, volume of injected bone cement, operation costs and hospital stays were all recorded. In addition, the Visual Analogue Scale (VAS) and the Oswestry Disability Index (ODI) were assessed separately for each patient before and after surgery. RESULTS: Compared with the PPSF + KP group, the PKP group had shorter operation time, less intraoperative blood loss, shorter hospital stays and fewer operation costs. However, cobb's angle improvement (13.4 ± 4.3° vs. 21.4 ± 5.3°), VWR improvement ratio (30.4 ± 11.5% vs. 52.8 ± 12.7%), HA (34.9 ± 9.0% vs. 63.7 ± 7.6%) and HM (28.4 ± 11.2% vs. 49.6 ± 7.7%) improvement ratio were all higher in PPSF + KP group than that in PKP group. In addition, the ODI index and VAS score in both groups were significantly decreased at the postoperative and final follow-up. PKP group's postoperative VAS score was significantly lower than that in PPSF + KP group, but there was no statistically significant difference in VAS score at the last follow-up. CONCLUSION: PKP and PPSF + KP can both effectively relieve the pain associated with sOVCF with nonunion. PPSF + KP can achieve more satisfactory vertebral reduction effects compared to PKP. However, PKP was less invasive and it has more advantages in shortening operation time and hospital stay, as well as decreasing intraoperative blood loss and operation costs.


Assuntos
Fraturas por Compressão , Cifoplastia , Fraturas por Osteoporose , Parafusos Pediculares , Fraturas da Coluna Vertebral , Humanos , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/cirurgia , Fraturas por Compressão/tratamento farmacológico , Perda Sanguínea Cirúrgica , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Fraturas da Coluna Vertebral/tratamento farmacológico , Resultado do Tratamento , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/cirurgia , Fraturas por Osteoporose/tratamento farmacológico , Cimentos Ósseos/uso terapêutico , Estudos Retrospectivos
11.
BMC Musculoskelet Disord ; 25(1): 294, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627655

RESUMO

PURPOSE: To assess the clinical safety, accuracy, and efficacy of percutaneous kyphoplasty (PKP) surgery using an enhanced method of unilateral puncture on the convex side for the treatment of painful osteoporotic vertebral compression fractures (P-OVCF) with scoliosis. METHODS: Clinical and radiographic data of P-OVCF patients with scoliosis who underwent PKP via unilateral puncture on the convex side from January 2018 to December 2021 were retrospectively analyzed. This technique's detailed surgical steps and tips were described. The local kyphosis angle (LKA), scoliosis Cobb angle (SCA), and local scoliosis Cobb angle (LSCA) were measured using X-ray and compared at pre-operation, post-operation, and the last follow-up. The width of pedicle (POW), inner inclination angle (IIA), lateral distance (LD), and puncture course length (PCL) were measured on the axial computed tomography image and compared between two sides. Postoperative computed tomography was employed to evaluate the condition of cement distribution and puncture. Clinical outcomes were evaluated using the Oswestry Disability Index (ODI) and Visual Analog Scale (VAS) for back pain (BP). RESULTS: Thirty-six patients, 23 women and 13 men, with an average age of 76.31 ± 6.28 years were monitored for 17.69 ± 4.70 months. The median surgical duration of single vertebrae was 35 min. The volume of bone cement for single vertebrae was 3.81 ± 0.87 ml and the proportion of sufficient cement distribution of the patients was 97.22. LKA was considerably improved from pre-operation to post-operation and sustained at the last follow-up. SCA and LSCA were not significantly modified between these three-time points. IIA, PCL, and LD were lower on the convex side than on the concave side. POW was considerably wider on the convex side. The ODI and VAS-BP scores were significantly improved after surgery and sustained during the follow-up. CONCLUSIONS: Combining with the proper assessment of the pre-injured life status of patients, PKP surgery using unilateral puncture on the convex side for the treatment of P-OVCF with scoliosis can achieve safe, excellent clinical, and radiographic outcomes.


Assuntos
Fraturas por Compressão , Cifoplastia , Cifose , Fraturas por Osteoporose , Escoliose , Fraturas da Coluna Vertebral , Masculino , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Cifoplastia/métodos , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/etiologia , Fraturas por Compressão/cirurgia , Escoliose/complicações , Escoliose/diagnóstico por imagem , Estudos Retrospectivos , Fraturas da Coluna Vertebral/complicações , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Resultado do Tratamento , Coluna Vertebral , Cimentos Ósseos/uso terapêutico , Punções , Cifose/diagnóstico por imagem , Cifose/etiologia , Cifose/cirurgia , Fraturas por Osteoporose/complicações , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/cirurgia
12.
PLoS One ; 19(4): e0301927, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38635748

RESUMO

Generally, UHS-ECC should consume massive cement, which is negative to its sustainability as cement production leads to 8% of global CO2 emissions. To decrease the cost of production and carbon emissions of UHS-ECC, rice husk ash was employed to replace the cement as a supplementary cementitious material in this study. Experiment results illustrate that blending rice husk ash (RHA) would decrease the fluidity of mortar. Furthermore, the green UHS-ECC shows a maximum compressive strength of 130.3 MPa at 28 days when RHA content was 20% of cement. The ultimate tensile strength of UHS-ECCs first increased and then decreased, while both tensile strain and strain energy presented an opposite tendency. At the micro-scale, if RHA content was lower than 20% of cement, incorporating RHA can significantly decreasing fiber bridging complementary energy of UHS-ECC, thus reducing pseudo strain hardening energy (PSHenergy) index, which finely agrees with the degradation of ductility of UHS-ECCs. To guarantee the features of ultra-high strength, acceptable workability, and high tensile ductility, the RHA dosage should not be in excess 20% of cement. These researched results are prospected to the contribution of pozzolanic RHA on the efficient usage of sustainable UHS-ECC.


Assuntos
Oryza , Cimentos Ósseos , Carbono , Força Compressiva , Cimentos de Ionômeros de Vidro
13.
BMC Musculoskelet Disord ; 25(1): 277, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600536

RESUMO

INTRODUCTION: The number of primary and revision Total Knee Arthroplasty (TKA) cases are expected to increase in future. There are various advantages and disadvantage to employing either of the two main types of stem fixation methods - cemented or hybrid technique. This review aimed to study the most optimal fixation method for revision TKAs by comparing radiological outcomes and re-revision rates. METHODS: A systematic review and meta-analysis was performed using PubMed and Cochrane Library from 2010 to identify studies explicitly comparing outcomes between cemented against hybrid fixation revision TKA techniques, with a minimum follow up of at least 24 months. A total of 8 studies was included in this review. Egger's test and visual inspection of the funnel plot did not reveal publication bias. RESULTS: There was no statistically significant difference in radiological failure and loosening (OR 0.79, CI 0.37-1.66, I2 = 29%, p = 0.22), all causes of re-revision (OR 1.03, CI 0.73-1.44, I2 = 0%, p = 0.56) and aseptic revision (OR 0.74, CI 0.27-2.02, I2 = 0%, p = 0.41) between cemented and hybrid techniques. Functional and pain outcomes compared between the two fixation techniques were largely similar across the studies included in this meta-analysis. CONCLUSION: Despite a trend favouring hybrid stems in revision TKA, current evidence revealed that radiological outcomes and re-revision rates are largely similar between cemented and hybrid fixation techniques.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Artroplastia do Joelho/métodos , Cimentos Ósseos/uso terapêutico , Exame Físico , Desenho de Prótese , Falha de Prótese , Reoperação/métodos , Resultado do Tratamento
14.
Medicine (Baltimore) ; 103(14): e37697, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38579049

RESUMO

BACKGROUND: Total knee arthroplasty involves the use of cemented tibial components for fixation. In recent years, cementless porous tantalum tibial components have been increasingly utilized. The aim of this meta-analysis was to compare the efficacy of cementless porous tantalum tibial components with traditional cemented tibial components in terms of postoperative outcomes following total knee arthroplasty. METHODS: Relevant literature was retrieved from Cochrane Library, PubMed, Embase, and Web of Science using the search terms "(trabecular metal OR Porous tantalum)" AND "knee" up to July 2023. The weighted mean difference with a 95% confidence interval was used as the effect size measure to evaluate the functional recovery of the knee joint, radiological analysis, complications, and implant revisions between cementless porous tantalum tibial components and traditional cemented tibial components after total knee arthroplasty. Review Manager 5.3 was utilized to conduct a comparative analysis of all included studies. RESULTS: Nine studies with a total of 1117 patients were included in this meta-analysis, consisting of 447 patients in the porous tantalum group and 670 patients in the cemented group. Radiological analysis demonstrated that the porous tantalum group had better outcomes than the cemented group (P < .05). The combined results for the 5-year and 10-year follow-ups, range of motion, Western Ontario and McMaster University Osteoarthritis Index, complications, and implant revisions showed no significant differences between the porous tantalum and cemented groups. CONCLUSION: The results of the 5-year and 10-year follow-ups indicate that the use of cementless porous tantalum tibial components is comparable to traditional cemented tibial components, with no significant advantages observed. However, at the 5-year follow-up, the porous tantalum group demonstrated a good bone density in the proximal tibia. Future studies with a larger sample size, long-term clinical follow-up, and radiological results are needed to verify the differences between the 2 implants.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Tantálio , Tíbia/cirurgia , Porosidade , Resultado do Tratamento , Articulação do Joelho/cirurgia , Desenho de Prótese , Cimentos Ósseos , Osteoartrite do Joelho/cirurgia
15.
Clin Interv Aging ; 19: 289-301, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38434576

RESUMO

Purpose: The purpose of this study is to compare the refracture rate of the cemented vertebral body of percutaneous curved vertebroplasty (PCVP) and bilateral percutaneous kyphoplasty (PKP) in the treatment of osteoporotic vertebral compression fractures (OVCF). Methods: Ninety-four patients with single segment thoracolumbar OVCF were randomly divided into two groups (47 patients in each) and underwent PCVP or bilateral PKP surgery, respectively. Refracture of cemented vertebral body, bone cement injection volume and cement pattern, cement leakage rate, total surgical time, intraoperative fluoroscopy time, preoperative and postoperative Cobb angles and anterior vertebral height, Oswestry disability index questionnaire (ODI) and visual analog scales (VAS) were recorded. Results: The PCVP group had significantly lower refracture incidence of the cemented vertebral than the bilateral PKP group (p<0.05). There was a significant postoperative improvement in the VAS score and ODI in both group (p<0.01), and no significant difference was found between two groups. The operation time and intraoperative fluoroscopy times were significantly less in the PCVP group than in the bilateral PKP group (p<0.01). The mean kyphosis angle correction and vertebral height restoration in the PCVP group was significantly less than that in the bilateral PKP group (p<0.01). Conclusion: Both PCVP and PKP were safe and effective treatments for OVCF. The PCVP had lower refracture rate of the cemented vertebral than the bilateral PKP group, and PCVP entailed less exposure to fluoroscopy and shorter operation time than bilateral PKP.


Assuntos
Fraturas por Compressão , Cifoplastia , Cifose , Fraturas da Coluna Vertebral , Humanos , Fraturas da Coluna Vertebral/cirurgia , Fraturas por Compressão/cirurgia , Coluna Vertebral , Cifose/cirurgia , Cimentos Ósseos/uso terapêutico
16.
J Orthop Surg Res ; 19(1): 169, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38448971

RESUMO

OBJECTIVE: The objective of this study is to investigate the impact of four natural product extracts, namely, aloe-emodin, quercetin, curcumin, and tannic acid, on the in vitro bacteriostatic properties and biocompatibility of gentamicin-loaded bone cement and to establish an experimental groundwork supporting the clinical utility of antibiotic-loaded bone cements (ALBC). METHODS: Based on the components, the bone cement samples were categorized as follows: the gentamicin combined with aloe-emodin group, the gentamicin combined with quercetin group, the gentamicin combined with curcumin group, the gentamicin combined with tannic acid group, the gentamicin group, the aloe-emodin group, the quercetin group, the curcumin group, and the tannic acid group. Using the disk diffusion test, we investigated the antibacterial properties of the bone cement material against Staphylococcus aureus (n = 4). We tested cell toxicity and proliferation using the cell counting kit-8 (CCK-8) and examined the biocompatibility of bone cement materials. RESULTS: The combination of gentamicin with the four natural product extracts resulted in significantly larger diameters of inhibition zones compared to gentamicin alone, and the difference was statistically significant (P < 0.05). Except for the groups containing tannic acid, cells in all other groups showed good proliferation across varying time intervals without displaying significant cytotoxicity (P < 0.05). CONCLUSION: In this study, aloe-emodin, quercetin, curcumin, and tannic acid were capable of enhancing the in vitro antibacterial performance of gentamicin-loaded bone cement against S. aureus. While the groups containing tannic acid displayed moderate cytotoxicity in in vitro cell culture, all other groups showed no discernible cytotoxic effects.


Assuntos
Antraquinonas , Produtos Biológicos , Curcumina , Emodina , Polifenóis , Gentamicinas/farmacologia , Cimentos Ósseos/farmacologia , Curcumina/farmacologia , Quercetina , Staphylococcus aureus , Antibacterianos/farmacologia , Produtos Biológicos/farmacologia
17.
Bone Joint J ; 106-B(2): 144-150, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38425304

RESUMO

Aims: The aim of this study was to determine both the incidence of, and the reoperation rate for, postoperative periprosthetic femoral fracture (POPFF) after total hip arthroplasty (THA) with either a collared cementless (CC) femoral component or a cemented polished taper-slip (PTS) femoral component. Methods: We performed a retrospective review of a consecutive series of 11,018 THAs over a ten-year period. All POPFFs were identified using regional radiograph archiving and electronic care systems. Results: A total of 11,018 THAs were implanted: 4,952 CC femoral components and 6,066 cemented PTS femoral components. Between groups, age, sex, and BMI did not differ. Overall, 91 patients (0.8%) sustained a POPFF. For all patients with a POPFF, 16.5% (15/91) were managed conservatively, 67.0% (61/91) underwent open reduction and internal fixation (ORIF), and 16.5% (15/91) underwent revision. The CC group had a lower POPFF rate compared to the PTS group (0.7% (36/4,952) vs 0.9% (55/6,066); p = 0.345). Fewer POPFFs in the CC group required surgery (0.4% (22/4,952) vs 0.9% (54/6,066); p = 0.005). Fewer POPFFs required surgery in males with a CC than males with a PTS (0.3% (7/2,121) vs 1.3% (36/2,674); p < 0.001). Conclusion: Male patients with a PTS femoral component were five times more likely to have a reoperation for POPFF. Female patients had the same incidence of reoperation with either component type. Of those having a reoperation, 80.3% (61/76) had an ORIF, which could greatly mask the size of this problem in many registries.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Masculino , Feminino , Artroplastia de Quadril/efeitos adversos , Fraturas Periprotéticas/epidemiologia , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Prótese de Quadril/efeitos adversos , Reoperação/efeitos adversos , Fatores de Risco , Desenho de Prótese , Cimentos Ósseos , Estudos Retrospectivos
18.
Sci Rep ; 14(1): 6716, 2024 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-38509345

RESUMO

Cement is the most widely used construction material due to its strength and affordability, but its production is energy intensive. Thus, the need to replace cement with widely available waste material such as incinerated black filter cake (IBFC) in order to reduce energy consumption and the associated CO2 emissions. However, because IBFC is a newly discovered cement replacement material, several parameters affecting the mechanical properties of IBFC-cement composite have not been thoroughly investigated yet. Thus, this work aims to investigate the impact of IBFC as a cement replacement and the addition of the calcifying bacterium Lysinibacillus sp. WH on the mechanical and self-healing properties of IBFC cement pastes. The properties of the IBFC-cement pastes were assessed by determining compressive strength, permeable void, water absorption, cement hydration product, and self-healing property. Increases in IBFC replacement reduced the durability of the cement pastes. The addition of the strain WH to IBFC cement pastes, resulting in biocement, increased the strength of the IBFC-cement composite. A 20% IBFC cement-replacement was determined to be the ideal ratio for producing biocement in this study, with a lower void percentage and water absorption value. Adding strain WH decreases pore sizes, densifies the matrix in ≤ 20% IBFC biocement, and enhances the formation of calcium silicate hydrate (C-S-H) and AFm ettringite phases. Biogenic CaCO3 and C-S-H significantly increase IBFC composite strength, especially at ≤ 20% IBFC replacement. Moreover, IBFC-cement composites with strain WH exhibit self-healing properties, with bacteria precipitating CaCO3 crystals to bridge cracks within two weeks. Overall, this work provides an approach to produce a "green/sustainable" cement using biologically enabled self-healing characteristics.


Assuntos
Saccharum , Silicatos , Compostos de Cálcio , Cimentos Ósseos , Bactérias , Água
19.
Med Eng Phys ; 125: 104137, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38508790

RESUMO

Osteoporosis is a common bone disease that often leads to difficulty in vertebrae revision. Traditional pedicle screws are often complicated to operate and have poor visibility during implantation. A new detachable pedicle screw is needed to improve the revision effect. The aim of this study was to design a new detachable pedicle screw based on medical optical imaging to improve the outcome of vertebral revision in osteoporosis, and to improve operational feasibility and visibility. In this study, the parameters related to the degree of osteoporosis were obtained by optical imaging detection of the osteoporotic vertebral body. Then a new detachable pedicle screw was designed according to the test results to improve the effect of vertebral body revision. By preparing and optimizing the material and structure of the screw, it is ensured that it has sufficient mechanical strength and stability. Finally, the visibility and operability of the improved screw during implantation were verified by medical optical imaging. Compared with traditional screws, the new detachable pedicle screw can improve the vertebral body revision in the case of osteoporosis. The optical imaging test results show that the new screw has good visibility and maneuverability, providing more accurate guidance and positioning for the vertebral body revision operation.


Assuntos
Osteoporose , Parafusos Pediculares , Humanos , Corpo Vertebral , Cimentos Ósseos , Fenômenos Biomecânicos , Osteoporose/diagnóstico por imagem , Osteoporose/cirurgia , Vértebras Lombares/cirurgia
20.
Br Dent J ; 236(6): 490, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38519688
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...